Why do plug blades come out of spec on length or spacing in some lots?

Common causes are tooling wear, a moulding process that moves the blades, inconsistent blade material or bending, and a change of supplier or lot.

Why does a charger miss its efficiency target at 10 percent load?

At light load the useful output is small, so fixed losses weigh more.

Why does burn-in find early failures from one component lot?

Burn-in runs units under stress to bring out weak parts early.

Why do charger labels peel or smudge after the climatic test?

The label material, adhesive, ink or the shell surface was not suited to heat and humidity.

Why does output voltage vary between units in the same batch under load?

Some variation is normal.

Why does a charger pass EMC in the lab but fail on a second batch?

The lab tested one sample.

Why does output ripple exceed the limit on a batch?

Ripple is the small fluctuation left on the DC output.

Why does flux residue appear on a charger board, and is it a defect?

Flux is used in soldering to help the solder flow, and some residue is normal, especially with no-clean fluxes.

Why does a surge test damage a charger that otherwise works?

A surge test applies a short, high-voltage pulse to the input to simulate lightning or switching events.

Why does a charger fail the high-temperature operating test?

A charger fails a high-temperature test when parts get too hot for their rating or the case exceeds its temperature limit.